FEATURES
* -20
℃to
650 , Wide range IR temperature
* Data hold function for
stored the desired value on display. measurement.
* Build the REL button,
useful for relative measurement.
* Infrared thermometer,
non-contact temperature
* Memory function to
record the maximum & minimum measurement, -20 to 650 ( -4 to 1202 ),℃
℃ ℉ ℉ reading with recall. precision
for none contact temperature measurement.
* RS 232 data output,
easy cooperate with computer.
* Emissivity adjustment
for IR thermometer.
* Optional data
acquisition software for data record.
* Laser guide for IR
thermometer.
* Auto power shut off
saves battery life.
* Red laser target guide
easy for the target identification.
* Built-in low battery
indicator.
* Microcomputer circuit
with high performance.
* Heavy duty & compact
housing case with stand.
* Build in &
select button on the front panel.℃
℉
* Operates from
006P DC 9V battery.
GENERAL
SPECIFICATIONS
Display 51 mm x 32 mm
supper large LCD
Distance Factor
D/S ratio : Approx. 7 : 1. display, 15 mm ( 0.6" ) digit size.
* D - Distance, S -
Spot. Over Indication Show " - - - - ".
Measurement Infrared
thermometer Data Output RS232 PC serial interface. ( Non contact
temperature measurement )
Power Supply Alkaline or
heavy duty type, Functions ,℃℉,
Data hold,
Memory ( Max., Min. ),
DC 9V battery,
006P, MN1604 ( PP3
) Relative measurement, or equivalent.
Emissivity adjustment (IR
thermometer).
Power Approx. DC
11 mA ( laser guide off ). Circuit Exclusive microcomputer circuit,
the Consumption Approx. DC 16 mA ( laser guide on ). software build
in linearity correction Operating 0 to 50 (32 to 122 ).℃
℉ instead the traditional hardware
circuit.
Temperature Emissivity
Range : 0.20 to 1.00. Operating Less than 80% RH.
Adjustment Adj. by
pushing button on front panel.
Humidity Laser Guide Red
laser light, less than 1 mW, Weight 220 g/0.48 LB. Meet EN60825
Dimension HWD 215 x 68 x
30 mm
. Sampling Time Approx.
1 second. ( 8.5 x 2.7 x 1.2 inch ).
Hold Function To freeze
the display reading value.
Standard Operational
manual......................1 PC. Memory
Recall Memorize the
Maximum, Minimum Accessory reading with recall. Optional
* Carrying case, Model :
CA-06, CA-03. IR Sensor Thermocouple pie. Accessories
* RS232 cable,
Model : UPCB-02. Measurement 6 to 12 micro meter.
* USB cable, Model :
USB-01 Wave Length
* Application software,
windows version. Region Model : SW-U801-WIN
OPTIONAL
ACCESSORIES
Carrying Case, CA-06
Model : CA-06, Hard carrying case Carrying Case, CA-03 Model :
CA-03, Vinyl soft carrying case. RS232 cable, UPCB-02 RS232 cable
for connecting between the meter & the computer. Application
Software, Windows software apply as the performance of data logging
system & data recorder... SW-U801-WIN |