FEATURES
*
Useful instrument to measure the surface
* Separate
probe, easy operation. & remote temperature of small size & narrow
spot target, measurement. such as IC, transistor, coil,
transformer...
* Super large
LCD display, easy readout.
*
Non-contact temperature measurement, wide
* Heavy
duty & compact housing case. range from - 10 to 300 (14 to 572 ),℃
℃ ℉ ℉
*
Records Maximum and Minimum reading wide temperature measuring for
general with recall. applications.
* Data hold.
* 0.1
/0.1 resolution.℃
℉
*
Operates from 006P DC 9V battery.
* ,℃℉
display
unit, select by front push button.
* Build the
RS232 serial interface output.
*
Emissivity value can adjust from 0.10 to 0.95. meter connect the
Personal Computer via the A factory preset emissivity value to 0.95,
RS232 cable & install the software, then whole which will cover
90% of a typical application. system will be used as the "DATA
LOGGER",
*
Microprocessor circuit assures max. possible "DATA RECORDER" or
other kinds modern accuracy, provides special functions & features.
temperature measuring system.
GENERAL
SPECIFICATIONS
Applications
Useful instrument to measure Sampling Time Approx. 1 sec.
the surface
temperature of Memory Recall Records maximum and small size target,
such as IC, minimum readings with transistor, coil, transformer...
recall.
Circuit Custom
one-chip of micro-Data Output RS232 serial PC interface.
processor
LSI circuit.
Operating Temp.
0 to 50
(32 to 122 ).℃
℃ ℉ ℉
Display LCD, 13
mm ( 0.5" ) digit size.
Operating Less
than 80% RH.
Resolution/ 1℃
-10 ℃
to 300
℃
Humidity ranges
1℉
14 ℉
to 572
℉
Power Supply
Heavy duty or Alkaline type, 0.1℃
-10.0
℃ to
110.0
℃ DC 9V
battery, 006P, MN1604 0.1℉
14.0 ℉
to 230.0
℉
( PP3 )
or equivalent.
Accuracy ± 2 %
of reading or ± 2℃
( 3
Power Current Approx. DC 4.8 mA. ), which ever is greater.℉
Weight 370
g/0.82 LB. * Within 23± 5
℃
ambient
Dimension Main instrument:
operating
temp. & a known 180 x 72 x 32 mm blackbody emissivity). (7.1 x 2.8
x1.3 inch). Measuring Approx. 10 mm ( 0.4 inch ) Sensor probe
: Distance
below the probe head. 148 x 36 x 36 mm .
Emissivity 0.10
to 0.95, A factory preset
Accessories
Instruction
manual........ 1 PC.
Setting
emissivity value to 0.95, which included IR Sensor probe............
1 PC.
will cover 90%
of a typical application.
Carrying
Case............... 1 PC.
Optional RS232
cable,
Temp. Sensor
Thermocouple pie. Model : UPCB-01 Measurement 6 to 12 micro meter.
USB cable, Wave
length Model : USB-01
Region
Application Software, Distance Factor D/S : 10 : 1. SW-U801-WIN D -
Distance, S - Spot.
OPERATIONAL
ACCESSORIES
RS-232 cable,
RS232 cable,
used for connecting the IR Thermometer & the Personal Model :
UPCB-01 computer ( com port )
USB cable,
USB
cable, used for connecting the IR Thermometer & the Personal Model :
USB-01 computer ( usb port ).
*
Application software is available for WIN 98, 2000, XP. Application
Software
* Setup the
hardware (IR thermometer + RS232 cable/USB cable + Model :
SW-U801-WIN Personal Computer + the software/SW-U801-WIN ), the
whole system can execute as a data logger, data recorder... . Data
can be retrieved for EXCEL... |